Cyclic Error - OKIDATA OL600e Service Manual

Hide thumbs Also See for OL600e:
Table of Contents

Advertisement

5

Cyclic Error

Image drum
Developing roller
Toner supply roller
Charging roller
Cleaning roller
Transfer roller
Heat roller
Back-up roller
Notes:
1.
After replacing the image drum cartridge, reset the drum counter.
2
After replacing the fusing unit assy, reset the fuser counter. OL610e/PS: See 4.1.
Troubleshooting
Frequency
3.71" (94.2 mm)
Replace or clean the image drum cartridge.
1.66" (44.4 mm)
Replace the image drum cartridge.
2.27" (57.8 mm)
Replace the image drum cartridge.
1.56" (39.6 mm)
Replace the image drum cartridge.
1.24" (31.4 mm)
Replace the image drum cartridge.
2.01" (51.0 mm)
Replace the transfer roller.
2.47" (62.8 mm)
Replace the fusing unit assy.
2.72" (69.08 mm)
Replace the back-up roller.
6 - 33
Remedy
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602

Advertisement

Table of Contents
loading

This manual is also suitable for:

610e610e-psOl610e-s

Table of Contents