(1) Remove the upper cover (see 3.3.1).
(2) Remove the lower base unit (see 3.3.7).
(3) Stand the lower base unit on its left side as shown. Free the pulse and main motor cables from
the lower base unit at location 3, , and unlock two clamp levers 2; then remove the motor
assembly 1.
Note: Use special care, because the idle gears and the reduction gear are not permanently
attached and will become loose.
Parts Replacement
Idle gear
2
3
Reduction gear
3 - 14