C.2.2
Service Tab
•
This portion of the DOS Operator Panel is available to service personnel only.
•
At the DOS prompt, enter: OL600 \S. When the Operator Panel appears, click on Service or
press the ALT and e keys.
(1) Head Drive Time
•
Sets the drive time of the LED head using a scroll bar.
•
For setting instructions, see page 4-3.
(2) LED Array
•
Leave at default setting–2560 Dots.
•
Alternate setting is for future development.
(3) LED Wires
•
Leave at default setting–1 Wire.
•
2 Wire settting is for future development.
•
Incorrect setting (2 Wire) causes two copies of the page image to be printed side by side.
(4) Climate
•
Adjusts fuser for environmental conditions.
•
Settings: +1 (default), 0, –1.
(5) Print Start Position
•
This setting is for shipping–do not change it.
(6) Market Place
•
Set at the factory for the region the unit will be shipped to:
ODA (US default): North & South America
OEL: Europe
Non-Europe 1: Australia
Non-Europe 2: Singapore, Far East
•
Must be set to ODA for proper default settings for language, symbol set, page size, etc.
•
If incorrectly set, menu page will read "OL600ex" or "OL610ex."
Diagnostics Test
C - 10
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602