3.3.14 Fusing Pressure Roller

(1) Remove the upper cover (see 3.3.1).
(2) Remove the stacker cover assembly (see 3.3.10).
(3) Remove the lower base unit (see 3.3.7).
(4) Remove the fusing unit assembly (see 3.3.13).
(5) Remove the motor assembly (see 3.3.8).
(6) Remove the reset lever R (see 3.3.10 for location). Press down on the fusing pressure roller to
take pressure off of the reset lever R.
(7) Lift the right side of the fusing pressure roller 1, and pull it out to the right side (at this time, two
bushings 2 and the bias springs 3 will release themselves).
Note:
Do not bend or lose springs.
Note the orientation and position of the bearings, springs, and ground clips.
2
3
Parts Replacement