Setting; Ol610E/Ps; Ol600E, Ol610E - OKIDATA OL600e Service Manual

Hide thumbs Also See for OL600e:
Table of Contents

Advertisement

Setting

Example: Method for setting the parameter to 19 (for case where the previous parameter
setting was 21).

OL610e/PS

Turn the POWER switch
on while holding the
FORM FEED and ENTER
keys down.
Press + or - key, until "19"
is displayed.
Press the ENTER key.
Turn the POWER switch on
while pressing the FORM
FEED and ENTER keys.

OL600e, OL610e

1.
At the DOS prompt, enter OL600 /S, then click on Service tab.
2.
On the Head Drive Time listbox, click the up arrow until 19 shows in the box.
3.
Click OK.
Adjustment
Operation
LCD display after operation
ENG MNT
LED HEAD
Displays previous
No. 21 *
parameter No.
LED HEAD
No. 19
Parameter 19 is
LED HEAD
set to EEPROM
No. 19 *
(* is displayed on
LCD).
4 - 5
OL600e/610e/610e-PS/610e-S
Service Manual, P/N 59271602

Advertisement

Table of Contents
loading

This manual is also suitable for:

610e610e-psOl610e-s