9–1d: MEQ Ctrl
MEQ Ctrl (MEQ Control Ch) [Ch01...16, G ch]
Selects the MIDI channel that will control dynamic
modulation (Dmod) for the master EQ.
G ch: The global MIDI channel "MIDI Channel" (GLOBAL
1–1a) will be used for control. Normally you will set this
parameter to G ch.
■ 9–1: UTILITY
☞"Write Combination," "Solo Selected Timbre" (0–1),
"Select by Category" (PROG 9–1)
Copy Master Effect
☞p.30 PROG 9–1
Note, the MIDI control channel that is specified by
"MFX1, 2 Control Ch" (9–1a) will not be copied.
Swap Master Effect
☞p.31 PROG 9–1
Note, the MIDI control channel that is specified by
"MFX1, 2 Control Ch" (9–1a) will not be swapped.
9–2: MFX1
(Master Effect1)
9–3: MFX2
(Master Effect2)
Here you can set the parameters of the "Master Effect1" and
"Master Effect2" effects that were selected in the Setup page
(☞p.104–).
■ 9–2(3): UTILITY
☞"Write Combination" (0–1)
9–4: MEQ
(Master EQ)
The master EQ is a three-band stereo EQ. It is located imme-
diately before the (MAIN OUTPUT) L/MONO and R from
the L/R bus, and adjusts the overall tonal character of the
sound (☞p.149). The MEQ High Gain and the MEQ Low
Gain can be controlled by assigning a modulation source to
the "Low Gain Mod-Src." and "High Gain Mod-src." func-
tions on this page.
■ 9–4: UTILITY
☞"Write Combination" (0–1)