Feature And Report Selections (For Partition 1) - GE NetworX V3 Installation Manual

Alarm system
Table of Contents

Advertisement

102
NetworX Version 3 Installation Manual
7 =
8 =
LOCATION 22 - DOWNLOAD CALL BACK NUMBER (20 segments, numerical data)
If a telephone number is programmed into this location, and "Require Call-back" is enabled in
location 21, the control panel will hang up for approximately 36 seconds (ensuring that the calling
party has disconnected), and then call back. The system will always wait for a dial tone unless the
first digit of the phone number is a "13"; in this case, it will only delay. Tone (DTMF) dialling is
default. If you want pulse tone dialling, program a "15" in the segment where pulse dialling should
begin. If the entire number should be pulse dialling, program a "15" in the first segment. Four-second
delays can be obtained anywhere in the sequence by programming a "13" in the appropriate delay
location.
Note: A zero is programmed as a "0".
Warning: You should always check that the callback phone number is accurate before disconnecting.

Feature and report selections (for partition 1)

LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feature
selection data)
Location 23 is used to enable certain features that the user can access or see from the keypad of the
system. In addition, certain communicator reports are enabled in location 23. Each of these features
can be enabled by partition. For additional partition information, see locations 88-109.
If the feature selection location for any partition is left blank, that partition will use this location for
the feature selection. This location contains 5 segments of 8 features each (see the feature
definitions).
Segment 1
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
Segment 2
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
On: locks out download section. (If "On", locations 19-22 cannot be viewed
from the keypad; can only be viewed from the keypad when "Off".)
On: enables call-back at auto test interval
On: enables the quick arm feature (for exit and stay mode)
On: enables the re-exit feature
On: enables the automatic bypass feature (of interior zones)
On: enables the silent keypad panic feature (overrides the audible panic
selection)
On: enables the audible keypad panic feature
On: enables the keypad Aux 1 feature (FIRE)
On: enables the keypad Aux 2 feature (MEDICAL)
On: enables the keypad multiple code attempt tamper feature (keypad
lockout)
On: enables the LED extinguish feature
On: enables the require code for bypassing feature
On: enables the zone bypassed sounder alert feature
On: enables the AC power/low battery sounder alert feature
On: enables bypass toggle
On: enables silent auto arm
On: enables the automatic instant feature (of entry/exit zones)
On: enables final set door