Chapter A2

Mains power connection

Use the mains connector terminal for connecting the mains supply. You can use a fixed cable or a
flexible mains lead to an earthed mains outlet. If fixed wiring is used, insert a dedicated circuit
breaker in the power distribution network. In all cases, the mains connection must comply with local
regulations.
WARNING: Disconnect the mains power before opening the cabinet.
To do this:
•Disconnect the AC mains plug from the AC mains wall socket.
•Disconnect the mains with the dedicated circuit breaker.
CAUTION: This unit can is provided with a lead battery inside. Batteries can explode or cause burns when
incorrectly (dis)assembled, or exposed to fire or high temperatures. Dispose of used battery
according to battery directive instructions and/or as required by local laws. Keep away from
children.
To replace the battery, please disconnect it and remove it from the holder. If required, replace
with the GE Security BS127N lead batery only. Do not use a different type of batteries.

Mounting

Ensure that the unit is mounted on a flat, solid, vertical surface so that the base will
not flex or warp when the mounting screws/bolts are tightened.
Leave a 50 mm clearance between equipment enclosures mounted side by side and 25
mm between the enclosure and the cable pathway.
The battery mounting facility inside the housing is only useful for steady state use of
the control panel. Remove the battery for transport of the control panel.