GE NetworX V3 Installation Manual page 265

Alarm system
Table of Contents

Advertisement

Message
Definition
Panel
The standby battery for the control
Low Battery
panel is low.
Panel
The control panel has detected an
Over-Current
excessive amount of current being
drawn from one of the outputs and has
disabled the output as a means of
protection.
Panel
The phone line connected to the control
Line Fault
panel is not working properly.
Panel
The mains power supply to the control
Mains Fault
panel is missing.
Panel
The connection to the control panel's
Siren Fault
siren is broken.
Remote
A reporting module tried to send a
Fail to
message to the central station but
Communicate
failed.
Remote
There has been interference with the
Box Tamper
casing of an expansion module.
Remote
The standby battery in an expansion
Low Battery
module is low.
Remote
The expansion module has detected an
Over-Current
excessive amount of current being
drawn from one of its outputs and has
disabled the output as a means of
protection.
Remote
The mains power supply is not
Mains Fault
connected to an expansion module
power supply.
Remote
The connection to an expansion
Siren Fault
module's siren is broken.
Remote
An expansion module or keypad is not
Trouble
reporting to the control panel.
Tamper
There is a problem with the wiring or
Zone X
the sensor is damaged.
Zone Problem
There is a problem with a zone or
Press OK
zones. Press OK to identify the zone(s)
and the problem condition.
One of the following messages is
displayed when you press OK.
NetworX Version 3 Installation Manual
Action
The battery may need replacing. This may be a
temporary condition caused by a long power
failure.
Check the system for wiring faults.
An overcurrent message can be reset only by
triggering the siren correctly, for example, by
generating a tamper on a zone that activates the
sirens. This is a security feature to ensure that the
overcurrent message has disappeared and the
sirens can work properly again.
Ensure that the phone line is connected properly.
Use a test phone to check proper service.
Reconnect the power supply and ensure it is
working properly.
Repair the open circuit.
Ensure that the phone line is connected properly.
Use a test phone to check that the phone service
is available. Ensure that the central station phone
number, account and protocol options are
correct. Check that the module is connected and
working.
Ensure that the casing is not damaged and is
mounted correctly on a flat surface. If there is no
damage, close the casing securely.
The battery may need replacing. This may be a
temporary condition caused by a long power
failure.
Check the module for wiring faults.
Reconnect the mains power supply and ensure it
is working properly.
Repair the open circuit.
Ensure that the module is connected properly to
the control panel.
Check the zone and zone sensors for damage and
repair any faults.
265