Programming The Keypad Sounder; Assigning Codes; Setting Up The Installer Code - GE NetworX V3 Installation Manual

Alarm system
Table of Contents

Advertisement

60
NetworX Version 3 Installation Manual
Navigate with the
2.
and press OK.
Scroll to Keyswitch Arming>Yes and press OK.
3.
The keypad beeps once to confirm the change and returns to Keyswitch Arming.
4.

Programming the keypad sounder

You can specify conditions and/or events that activate the keypad sounder. To configure the sounder,
you must enable the advanced menu. The following example programs the keypad sounder to
activate when an expander trouble condition occurs.
Ensure the advanced menu is enabled.
1.
Navigate with the
2.
OK.
Scroll to Expander Trouble>Enabled and press OK.
3.
The keypad beeps once to confirm the change and returns to Expander Trouble.
4.

Assigning codes

Figure 17. Installer codes menu
2.3.1
4/6 Digit Codes
Installer Code
2.3.2
Duress Code
2.3.3
Guard Codes 16 17
User Auth for Progrm.
System codes can be either four or six digits long. This menu allows to program/change the installer
code and the duress code. A duress code disarms the system and activates a duress alarm. This is a
silent alarm that sends a special report to the central station. To program codes, select Installer
Menu>Control Panel>Codes.
Note: For EN/INCERT compliance, system access ID needs to be in 6 digit format.

Setting up the installer code

An installer code may have associated arming options and access rights. To set the authority and
access rights, you must enable the advanced menu. The following example assigns partitions 1 and 2
to a new installer code that can be used only to arm the system.
Ensure the advanced menu is enabled.
1.
Navigate with the
2.
OK.
keys to Control Panel>Outputs>Internal Siren>Short Blast On
keys to Control Panel>Outputs>Keypads>Sound On and press
Code
2.3.2.1
Authority
2.3.2.2
2.3.2.2.1
2.3.2.2.2
2.3.2.2.3
2.3.2.2.4
2.3.2.2.5
2.3.2.3
2.3.2.2.6
Partitions
keys to Control Panel>Codes>Installer Code>Code and press
Arm Only After Closing
Arm Only
Arm/Disarm
Master Code
Bypass Zones
Reports Open/Close

Hide quick links:

Advertisement

Table of Contents
loading