Telephone Number 3 - GE NetworX V3 Installation Manual

Alarm system
Table of Contents

Advertisement

98
NetworX Version 3 Installation Manual
LOCATION 10 - EVENTS REPORTED TO PHONE N° 2 (2 segments of feature selection data)
Segment 1
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
Segment 2
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
LOCATION 11 - PARTITIONS REPORTED TO PHONE N° 2 (1 segment, feature selection data)
Location 11 is used when events to be reported to a phone number are based on the partition,
regardless of the event. If this location is used, location 10 should be "0".
Segment 1
1 =
2 =
3 =
4 =

Telephone number 3

LOCATION 12 - PROGRAMMING PHONE N° 3 (20 segments, numerical data)
Phone N°3 is programmed in location 12. A "14" indicates the end of the phone number. Delays of
four seconds can be programmed at any point in the phone number by programming a "13" in the
appropriate segment. The system will always wait for a dial tone unless the first digit of the phone
number is a "13"; in this case, it will only delay. Tone (DTMF) dialling is default. If you want pulse
tone dialling, program a "15" in the segment where pulse dialling should begin. If the entire number
should be pulse dialling, program a "15" in the first segment. Program an "11" for a "*", and a "12"
for a "#".
Note: A zero is programmed as a "0".
Alarms
Opening and closings
Zone bypass and bypass restores
Zone trouble and trouble restores
Power fail (AC failure), low battery, power restore (AC restore) , and low
battery restore
Bell cut, bell cut restore, telephone line restore
Test reports
Start and end programming, download complete and log full
Zone and box tamper
Auxiliary power overcurrent, and restore
Wireless sensor missing and restore
Wireless sensor low battery and restore
Expander trouble and restore (keypads are considered as expanders)
Fail to communicate
Alarm restore
Tamper restore
Partition 1
Partition 2
Partition 3
Partition 4