Auxiliary Current And Battery Capacity - GE NetworX V3 Installation Manual

Alarm system
Table of Contents

Advertisement

14
NetworX Version 3 Installation Manual
Standard onboard outputs
Built-in Siren Driver (BELL+, BELL-)
High current outputs (RLY1 and RLY2)
Control panel fuses
Battery
AUX PWR+
POS
Mains, mains fuse [4]
Environmental
Operating temperature
Humidity
IP protection grade
Colour
Dimensions
Shipping weight
EN 50131 grade and class
General features
Code combinations [6]
End-of-line resistor
Data retention (log, program settings)
[1] Current available for AUX PWR+, POS and battery charge outputs (non-EN-mode).
[2] Maximum permanent current to power devices external to the control equipment in the absence of alarm
conditions (EN-mode).
[3] Max ripple voltage only when empty battery is charging.
[4] Mains fuse is a part of the mains terminal block.
[5] Minimum voltage only when mains supply voltage is disconnected and system is running on battery.
[6] There are no disallowed codes.
[7] Optional function for the EN 50131 compliance.
WARNING: Before removing the mains fuse, mains power must be disconnected.

Auxiliary current and battery capacity

Table 3.
NX-xx(-GSM)-EUR maximal available auxiliary current
Battery
Discharge
Time (h)
12
NX-xx(-GSM)-EUR
NX-xx(-GSM)-EUR
315 mA, T 250V 20x5
NX-xx(-GSM)-EUR
220 x 253 x 112 mm
NX-xx(-GSM)-EUR
7.2 Ah
Charge
Auxiliary current (mA)
Time (h)
72
350
Electronic output, rating: 1 A at 13.8 V
Relay, rating: 1 A at 13.8 V
5 A, resettable
1 A, resettable
1 A, resettable
−10 to +55°C
Max 95% non condensing
IP30
Beige
1.8 kg
Securuty Grade 2, Environmental Class II
From 10,000 (4 digits) to 1 million (6 digits)
3.3 kΩ
20 years
NX-xx(-GSM)-LB-EUR
± 10%
± 10%
NX-xx(-GSM)-LB-EUR
630 mA, T 250V 20x5
NX-xx(-GSM)-LB-EUR
394 x 256 x 118 mm
2.8 kg
NX-xx(-GSM)-LB-EUR
EN 1&2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetworX V3 and is the answer not in the manual?

Table of Contents

Save PDF