GE NetworX V3 Installation Manual page 83

Alarm system
Table of Contents

Advertisement

Location
Term
2.4.4.2.1.4
RF Sensor Lost
2.4.4.2.1.5
RF Low Battery
2.4.4.2.1.6
CleanMe
2.4.4.2.2
Power
2.4.4.2.2.1
Mains Failure
2.4.4.2.2.2
Low Battery
2.4.4.2.2.3
Aux Overcurrent
2.4.4.2.3
Communications
2.4.4.2.3.1
Phone Line Cut
2.4.4.2.3.2
Fail to Communicate
2.4.4.2.3.3
Autotest
2.4.4.2.3.4
Autotest only when Armed
2.4.4.2.4.1
Log Full
2.4.4.2.4.2
Start/End Programming
2.4.4.2.4.3
End Download
2.4.4.2.5
Bypass on Force Arm
NetworX Version 3 Installation Manual
Definition
A menu option that sends a report to the central station,
when an RF sensor is missing.
RF sensors send out supervision signals every 15 or 64
minutes, depending on the frequency. An RF receiver must
receive these signals within a specified time window. This
window is set by the Supervision timer. If the RF receiver
does not receive these signals during the time window, the
RF sensor is considered missing.
A menu option that sends a report to the central station
when a low battery condition occurs in an RF sensor.
A menu option that sends a report to the central station
when a smoke detector is dirty.
A menu entry that groups the power events that are
reported to the central station.
A menu option that sends a report to the central station
when the mains power supply fails. A delay time can be set
for this report.
A menu option that enables low battery reporting on the
control panel.
A menu option that enables overcurrent reporting. A report
is sent to the selected central station when too much
current is drawn from a device powered by the system.
A menu entry that groups together the communication
events that are reported to the central station.
A menu option that sends a report is sent to the central
station the moment the phone line cut is restored.
A menu option that sends a report to the central station
when the system has failed to communicate with the
central station after the number of attempts set in Dial
Attempts. The report is sent when communication with the
central station has been restored.
A menu option that enables reporting of autotest events to
the central station at a specified interval.
A menu option that allows test calls to be made only when
the system is armed.
A menu option that sends a report to the central station
when the event log is full.
A menu option that causes reports to be sent to a specified
phone number. A report is sent when local programming
begins and ends.
A menu option that sends a report to the central station
when downloading from the up/download software to the
control panel is complete.
A menu option that enables bypass reporting when a zone
is force armed.
83