Programming A Location; Exiting The Program Mode - GE NetworX V3 Installation Manual

Alarm system
Table of Contents

Advertisement

46
NetworX Version 3 Installation Manual
of module numbers on page 261. The procedure for programming these devices is the same as for the
control panel, except that the location will be for the module selected.

Programming a location

Note: Before programming the panel, the correct country code must be set in location 213 or through the
installer menu, with This Keypad>Load Country Defaults menu option. It is selected during the first
keypad installation, see Wireless keypad learning-in procedure on page 32.
Once you have entered the number of the module to be programmed, the LCD screen will prompt
you for a location number. Any location can be accessed by directly entering the desired
programming location, followed by the crosshatch (pound) [#] key. If the location you enter is valid,
the top line of the LCD screen will display the location number on the left and the segment number
on the right. The bottom line of the display will show the current data. This data will be displayed
and entered according to the type of data used (numerical, binary, or character data). For instructions
about entering each type of data, see Changing a menu option on page 41. If editing data, confirm the
change by pressing the OK key.

Exiting the program mode

When you have made all the desired changes in programming, it is time to exit the program mode.
Press the NO key twice to exit this programming level, and go to the "Enter the device address"
level. If no additional modules are to be programmed, press the NO key twice again to display the
OK to Exit prompt, and press OK to exit the program mode. If there is another module to be
programmed, you can select it by entering its address, followed by the [#] key (see Selecting the
module to program above).
Note: If you are not in a value selection mode nor in a value edit mode, you can press ## to display the OK to Exit
prompt. It also means you can exit any menu level immediately and display the OK to Exit prompt by
pressing [NO] [#] [#].
Note: You can set up the timeout for the program mode using the Control Panel>System
Settings>Timers>Miscellaneous>Programming Mode Timeout menu option, or by programming location
40, segment 14.