GE NetworX V3 Installation Manual page 190

Alarm system
Table of Contents

Advertisement

190
NetworX Version 3 Installation Manual
LOCATIONS 150-159 - AUTHORIZING USERS 1 - 99 TO TRIGGER OUTPUTS 1 - 8 (10 segments,
feature selection data)
When activating outputs with a user code (event 45), locations 150-159 can be used to restrict certain
codes from activating certain outputs. Each location contains 10 segments. Segment 1 corresponds to
user 1, segment 10 corresponds to user 10. The LED's correspond to outputs 1 - 8.
Location
Segments
150
10
151
10
152
10
153
10
154
10
155
10
156
10
157
10
158
10
159
10
Option
1
2
3
4
5
6
7
8
Type
Function
AUTHORIZING USERS 1 - 10 TO TRIGGER OUTPUTS 1 – 8
option
Segment 1 – user 1, segment 2 – user 2 ..... segment 10 – user 10
AUTHORIZING USERS 11 - 20 TO TRIGGER OUTPUTS 1 – 8
option
Segment 1 – user 11, segment 2 – user 12 ..... segment 10 – user 20
option
AUTHORIZING USERS 21 - 30 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 31 - 40 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 41 - 50 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 51 - 60 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 61 - 70 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 71 - 80 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 81 - 90 TO TRIGGER OUTPUTS 1 - 8
option
AUTHORIZING USERS 91 - 99 TO TRIGGER OUTPUTS 1 - 8
Function
ON
Code will activate Output 1
OFF
Code will NOT activate output 1
ON
Code will activate Output 2
OFF
Code will NOT activate output 2
ON
Code will activate Output 3
OFF
Code will NOT activate output 3
ON
Code will activate Output 4
OFF
Code will NOT activate output 4
ON
Code will activate Output 5
OFF
Code will NOT activate output 5
ON
Code will activate Output 6
OFF
Code will NOT activate output 6
ON
Code will activate Output 7
OFF
Code will NOT activate output 7
ON
Code will activate Output 8
OFF
Code will NOT activate output 8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents