-66 Motor stalled skew
Motor count issue
Issue: skew counter is not working properly
1. Ensure the controller has firmware version 3.9.0 or higher and perform a test dish from the
DATASTORM% prompt.
2. Perform nvclear command from the J1boot% prompt in a telnet session power cycle the unit
and reconfigure the controller.
3. Contact MotoSAT support for possible parts replacement.
-67 Azimuth Motor Speed Failed
Motor Speed testing in test dish, set mot speed and mot current retest
Mount, motors, controller
--68 Elevation Motor Speed Failed
Motor Speed testing in test dish, set mot speed and mot current retest
Mount, motors, controller
-69 Halt Line Failure
-70 Motor Overcurrent Elevation
Set motor currents in telnet or Config
Replace bad motor or mount, or controller
71 Motor Overcurrent Skew
-
Set motor currents in telnet or Config
Replace bad motor or mount, or controller
86