1. Power cycle the controller and check connections at the mount and on the controller.
2. Perform stow dish operation.
3. Ensure the controller has firmware version 3.9.0 or higher and perform a test dish from the
DATASTORM% prompt.
4. Perform nvclear command from the J1boot% prompt in a telnet session, power cycle the unit
and reconfigure the controller higher and perform a test dish from the DATASTORM% prompt..
5. Contact MotoSAT support for possible parts replacement.
-54 SK Motor Limit
Test dish, check man counts. Stow replaces controller.
Issue: The skew motor reached its limit prematurely.
Resolutions:
1. Power cycle the controller and check connections at the mount and on the controller.
2. Perform stow dish operation.
3. Ensure the controller has firmware version 3.9.0 or higher and perform a test dish from the
DATASTORM% prompt.
4. Perform nvclear command from the J1boot% prompt in a telnet session, power cycle the unit
and reconfigure the controller higher and perform a test dish from the DATASTORM% prompt..
5. Contact MotoSAT support for possible parts replacement.
-55 Azimuth is not at the limit
XF Mount.. read sensors, test mount, replace controller
Issue: Azimuth limits sensor failure.
Resolutions:
1. Power cycle the controller and check connections at the mount and on the controller.
2. Perform stow dish operation.
3. Ensure the controller has firmware version 3.9.0 or higher and perform a test dish from the
DATASTORM% prompt.
4. Perform nvclear command from the J1boot% prompt in a telnet session, power cycle the unit
and reconfigure the controller higher and perform a test dish from the DATASTORM% prompt..
5. Contact MotoSAT support for possible parts replacement.
-56 Elevation is not at the limit
XF Mount.. read sensors, test mount, replace controller
Issue: Elevation limits sensor failure.
Resolutions:
1. Power cycle the controller and check connections at the mount and on the controller.
2. Perform stow dish operation.
3. Ensure the controller has firmware version 3.9.0 or higher and perform a test dish from the
DATASTORM% prompt.
4. Perform nvclear command from the J1boot% prompt in a telnet session, power cycle the unit
and reconfigure the controller higher and perform a test dish from the DATASTORM% prompt.
5. Contact MotoSAT support for possible parts replacement.
-57 SNR Not Available
83