8.2 Pre-quenching Corona Wire Replacement

1. Remove the pre-quenching corona unit.
2. Remove the rear endblock cover [A].
3. Remove the front endblock cover [B] and take the old corona wire [C] off the front spring
[D] .
4. Pull the rear spring [E] out of the rear endblock [F], and remove the old quenching corona
wire.
5. Install a new corona wire.
6. Reassemble the quenching corona unit.