4-Bit Bias Control Signal
BIT 4
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
NOTE: SP34 shifts the bias under all conditions. There are three settings: 0, 60, and 120.
5.7 RELATED SERVICE CALL CONDITIONS
Code #31: Drum Thermistor Blown
Definition:
Lights when the drum thermistor circuit is open.
Points to Check:
Check the resistance between CN36-3 and CN36-D on the ID sensor board.
(Reference value: 10 kohms at 25°C)
Check CN103-13 on the main PCB.
BIT 3
BIT 2
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
BIT 1
Bias Output
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
710
2-37
31 August 1989
260
290
320
350
380
410
440
470
500
530
560
590
620
650
680