1. INSTALLATION REQUIREMENTS

1.1 ENVIRONMENT

1. Temperature Range:
2. Humidity Range:
3. Ambient Illumination:
4. Ventilation:
5. Ambient Dust:
6. Room size
7. If the place of installation is air-conditioned or heated, place the machine
a) where it will not be subjected to sudden temperature changes.
b) where it will not be directly exposed to cool air from an air conditioner.
c) where it will not be directly exposed to reflected heat from a heater.
8. Do not place the machine where it will be exposed to corrosive gasses.
9. Do not install the machine at any location over 2,000 m (6,500 feet) above sea level.
10. Place the copier on a strong and level base.
11. Do not place the machine where it may be subjected to strong vibrations.
10°C to 30°C (50°F to 80°F)
15% to 90% RH
Less than 1,500 Iux (Do not expose to direct sunlight.)
Room air should turn over at least 3 times/hour.
Less than 0.15 mg/m³ (4 x 10¯³ Oz/yd³)
More than 10 m³ (13.4 yd
3-1
3
)
31 August 1989