10. Disconnect CN406 [A], CN408 [B], and CN409 [C] on the feed control board.
11. Connect the six tray harness connectors to the three free harness connectors and to the
three connectors on the feed control board as follows:
TRAY
Female 4P
Female 10P
Female 12P
TRAY
Male 4P
Male 10P
Male 12P
12. Secure the harness to the copier table with the nylon clamp [D] (1 screw).
CONTROL BOARD
CN408
CN406
CN409
FREE
4P
10P
12P
10-13
31 August 1989