14.2 Inverter Turn Gate SoIenoid Adjustment
Adjustment Standard: 1.5 ± 0.5 mm
1. Remove the DF upper cover (4 screws).
2. Manually energize the inverter solenoid [A].
3. Loosen the screw [B] and adjust the position of the inverter solenoid to bring the gap [D]
between the turn gate [E] and the guide plate [F] within the adjustment standard.
4. Tighten the screw and install the DF upper cover.
8-27
31 August 1989