31 August 1989
9. Thread the wire between the two pulleys [A].
10. Position the first and second scanners according to the adjustment table, and secure the
first scanner wire clamp (rough adjustment of the horizontal magnification).
11. Adjust the horizontal magnification using SP 44. (Refer to "Horizontal Magnification Adjust-
ment.")
12. Adjust the focus with SP 47. (Refer to "Focus Adjustment.")
13. Reassemble.
5-7