4.
Enter 1=On or 0=Off in the MISC field.
1 turns the contact on: if a normally open contact, on closes the
contact; if a normally closed contact, on opens the contact.
0 turns the contact off: if a normally open contact, off opens the
contact; if a normally closed contact, off closes the contact.
5.
Enter a dwell time (0-99 seconds) in the DWELL field.
Dwell time is the amount of time you want the CCU to wait before it
performs the next step in the MultiCall. A "00" dwell time tells the
CCU to perform the functions at the same time. A "15" second
dwell time means that the CCU will wait 15 seconds before
performing the next step in the MultiCall.
6.
Enter another function or press Enter to end programming. If you
pressed Enter, press S to save programming or press Esc to end
programming without saving.
PROGRAMMING MULTICALLS
4-17