monitor or record the alarm site before acknowledging the alarm.
The alarm acknowledge function can occur anywhere in the
MultiCall after the alarm monitor and alarm record functions.
Usually it is the last function programmed. For example, a PreShot
or a VectorScan may occur prior to acknowledging the alarm.
5.
Enter another function or press Enter to end programming. If you
pressed Enter, press S to save programming or press Esc to end
programming without saving.
AUTOMATICALLY ACKNOWLEDGE AN ALARM
If you want the MultiCall to automatically acknowledge the alarm,
perform the following steps.
1.
Enter C in the FUN field.
2.
Enter AA in the NUM column.
3.
Enter a dwell time in the DWELL field.
Dwell time is the amount of time you want the CCU to wait before it
performs the next step in the MultiCall. A "00" dwell time tells the
CCU to perform the functions at the same time. A "15" second
dwell time means that the CCU will wait 15 seconds before
performing the next step in the MultiCall. Usually the AA function is
the last step in the MultiCall.
4.
Enter another function or press Enter to end programming. If you
pressed Enter, press S to save programming or press Esc to end
programming without saving.