Rs-485 Control Output Interface; Ultrak Hd Series Video Switcher Interface - Ultrak CCU-100HD User Manual

Central control unit
Table of Contents

Advertisement

3.2.2

RS-485 Control Output Interface

The Model CCU -100 Central Control Unit sends all control data for
FastScan or SmartScan assemblies and CRX-500 or CRX-800 assemblies
from the operators at the JPD-100 Controllers and from MultiCalls out
channels 4, 6, and COM2. All the receivers connected to channels 4 and 6
receive the control data; only the receiver with the address responds to the
command. The HD switcher receives the control data sent out COM2. The
HD switcher converts the data (if necessary) to the protocol required by the
pan and tilt units connected to the video switcher control outputs. Refer to
the HD series manual for selecting the pan and tilt protocol.
3.2.3

Ultrak HD Series Video Switcher Interface

The CCU-100/HD Central Control Unit communicates with an Ultrak HD
Series Switcher at COM2. This interface provides switching of 128 cameras
to 32 monitors, programming the video alarms monitored by the HD switcher,
and controlling pan and tilt cameras connected to the switcher. If the MX-
4248 optional I/O module is installed on the video switcher, the CCU
supports responding to the 24 alarm inputs and controlling the eight contact
outputs.
The switcher can be controlled by an operator at a JPD-100 Joystick
Controller or automatically by commands entered in MultiCalls stored in the
CCU. Refer to Section 4, paragraph 4.3.3.1 and 4.3.3.2 to program
automatic commands for Diamond series FastScan/SmartScan pan and tilt
units. Refer to Section 4, paragraph 4.3.3.4 of this manual to program video
switching commands in MultiCalls. Refer to paragraph 4.3.3.5 of this manual
3-5