4.3.3.3
M - MultiCall
To program the MultiCall to perform a MultiCall (including itself), perform
the following steps.
1.
2.
3.
4.
If the cursor does not automatically move to
the next field after entering data in a field,
press the right gray arrow key to move to the
next field.
Enter M in the FUN field.
Enter the MultiCall Number (0-255) in the NUM field.
Enter a dwell time (00-99 seconds) in the DWELL field.
Dwell time is the amount of time you want the CCU-100 to wait
before it performs the next step in the MultiCall. A "00" dwell time
tells the CCU-100 to perform the functions at the same time. A
"15" second dwell time means that the CCU-100 will wait 15
seconds before performing the next step in the MultiCall.
One MultiCall can start another MultiCall. If a MultiCall calls itself, it
will repeat until halted by an operator. If the MultiCall calls itself,
that step should be the last entry in a MultiCall. Note: Refer to the
JPD-100 Joystick Controller User's Manual for stopping MultiCalls.
Enter another function or press Enter to end programming. If you
pressed Enter, press S to save programming or press Esc to end
programming without saving.