SETTING UP ALARM MONITORS/VCRS
4-32
4.4

SETTING UP ALARM MONITORS AND VCRs.

The CCU can be programmed to designate monitors as alarm monitors (AM) and
VCRs as alarm VCRs (AR). See paragraph 3.2.5 in Section 3 of this manual for
the operating procedures for the alarm monitors and alarm VCRs.
To setup alarm monitors and alarm VCRs, perform the following steps.
1.
Press Shift F12.
Note: If outputs have been previously programmed the programming will
be displayed. The CCU-100 accepts up to 10 video outputs for alarm
monitors. The video outputs must be in sequential order. For example, if
the first alarm monitor is 3, then the last alarm monitor must be 3 or
greater (up to 12). The system does not accept incorrect entries.
The CCU-100 will accept up to eight VCR video outputs. These video
outputs must be in sequential order. The system does not accept
incorrect entries. The Alarm VCR Control Outputs (up to 8) designate
which auxiliary outputs on the HD I/O Module the VCRs are connected to.
The VCRs must be connected to consecutive contact outputs on the HD
video switcher. There are the same quantity of Alarm VCR CNTRL
The Alarm VCRs must be connected to the
contact outputs on the HD video switcher.
NOTE