A - Auxiliary Output Control (such as VCRs)

The auxiliary output control function is used to energize or de-energize
relays to turn on or off auxiliary devices such as VCRs. The auxiliary
devices must be connected to a unit that contains contact outputs for
this purpose. The HD series video switcher has eight optional auxiliary
outputs, the AIF-100/CO has eight auxiliary outputs, the CRX-800 Series
Control Receivers have six auxiliary outputs and CRX-500 Series
Control Receivers have two auxiliary outputs. To control an auxiliary
device, the programmer must know the address of the contact output
device (AIF-100/CO, or CRX-800) and the number of the contact output
the auxiliary device is connected to. The addresses of the AIF-100/CO,
CRX-500, and CRX-800 units are DIP switch selectable like the
FastScan/SmartScan units.