APPENDIX B. PROGRAMMING AIF-100 ALARM INPUTS

B.1

GENERAL

This appendix provides the programming information for the AIF-100/IN Alarm
Input Auxiliary Interface Unit, the AIF-100/AL Alarm Input Auxiliary Interface Unit,
and the AIF-100/IO Alarm Input/Contact Output Auxiliary Interface Unit. The
AIF-100/IN unit can be wired directly to the CCU-100 Central Control Unit and
operates the same as an AIU-100 Alarm Interface Unit. The AIF-100/AL and
AIF-100/IO units must be wired to an AIF-100/CI CCU Auxiliary Interface Unit for
communication with the CCU-100 Central Control Unit.
The programming menus on the CCUs are designed for use with AIU-100 Alarm
Interface Units. Each AIU-100 unit has thirty-two alarm inputs. Up to eight AIU-
100 units can be daisy-chained together to provide a total of up to 255 alarm
inputs. The same menus used for programming AIU-100 Alarm Interface Units
are used for programming the AIF-100/IN, AIF-100/AL, and AIF-100/IO alarm
inputs. So the programmer has to know the equivalency between the AIF-100
units and the AIU-100 units. The following paragraphs explain the equivalencies
between the different units and provide the steps for programming the alarm
inputs. Examples are given for assistance during programming.
B.2

AIF-100/IN ALARM INPUT AUXILIARY INTERFACE UNIT

One AIF-100/IN Alarm Input Auxiliary Interface Unit is equivalent to one AIU-100
Alarm Interface Unit. Each AIF-100/IN has eight alarm inputs. Alarm inputs nine
through thirty-two on the programming menu are not used or programmed. The
CCU-100 Central Control Unit supports the programming for up to eight AIF-
100/IN Alarm Input Units. Up to a total of eight AIF-100/IN Alarm Input Auxiliary
Interface Units and AIU-100 Alarm Interface Units can be daisy-chained
together.
Each unit must be given a unique address between 0 and 7 for
programming of alarm inputs.