Ultrak CCU-100HD User Manual page 101

Central control unit
Table of Contents

Advertisement

OUTPUTS as ALARM VCR VIDEO OUTPUTS. The control outputs are
used to turn the VCRs on and off.
2.
Enter the first video output and the last video output on the video
switcher for the alarm monitors. If you enter 3 for the first number and 7
for the last number, video outputs 3, 4, 5, 6, and 7 are setup as alarm
monitors.
3.
Enter the first video output and the last video output on the Video
Switcher for the alarm VCRs. If you enter 8 for the first number and 9 for
the last number, video outputs 8 and 9 are setup as alarm VCRs.
4.
Enter the first contact output number (1-8) that the first VCR is
connected to on the MX-4248 I/O Board on the HD switcher. The CCU
fills in the last contact output number based on the number of alarm VCR
outputs programmed. For example, the alarm VCRs are connected to
contact outputs 1 (Alarm VCR Video Output 8) and 2. (Alarm VCR Video
Output 9).
5.
Press Enter when done.
SETTING UP ALARM MONITORS/VCRs
4-33