The alarm inputs on AIF-100/AL address 1 are AIU 0, 9 through 16. These will
appear on the JPD-100 display as alarm 9 through 16.
The alarm inputs on AIF-100/AL address 2 are AIU 0, 17 through 24. These will
appear on the JPD-100 display as alarms 17 through 24.
The alarm inputs on AIF-100/AL address 3 are AIU 0, 25 through 32. These will
appear on the JPD-100 display as alarms 25 through 32.
Alarm inputs 1 through 8 on AIF-100/AL address 4 are AIU 1, 1 through 8.
These will appear on the JPD-100 display as alarms 33 through 40.
Alarm inputs 1 through 8 on AIF-100/AL address 5 are AIU 1, 9 through 16.
These will appear on the JPD-100 display as alarms 41 through 48.
Alarm inputs 1 through 4 on AIF-100/IO address 6 are AIU 1, 17 through 20.
These will appear on the JPD-100 display as alarms 49 through 52.
Alarm inputs 1 through 4 on AIF-100/IO address 7 are AIU 1, 25 through 28.
These will appear on the JPD-100 display as alarms 57 through 60.
EXAMPLE 2:
There are two AIF-100/CI's, addressed as 0 and 1, connected to the CCU-100
Central Control Unit.
a.
The AIF-100/CI, addressed as 0, has two AIF-100/AL units addressed 0
and 1, and two AIF-100/IO units addressed as 2 and 3. There are a total of
24 alarm inputs. This AIF-100/CI replaces one AIU-100 Alarm Interface
Unit.
1.
Alarm inputs 1 through 8 on AIF-100/AL addressed as 0 are AIU 0,
alarm inputs 1 through 8. These alarms will appear on the JPD-100
display as alarms 1 through 8.
B-7