1.15 MECHANICAL COUNTER (NA ONLY)

1.15.1 INSTALLATION PROCEDURE

1.
Rear cover (see "Rear Cover" in the "Replacement and Adjustment" section)
2.
Right rear cover (see "Right Rear Cover" in the "Replacement and Adjustment"
section)
3.
PSU bracket (see "PSU" in the "Replacement and Adjustment" section)
4.
Install the mechanical counter for Bk [A] in the right frame of the machine.
5.
Connect the harness [B] to the mechanical counter for Bk.
6.
Route the harness as shown with clamps, and then connect it to CN260 on the
IOB.
7.
Install the mechanical counter for Full Color [C] in the bracket [D].
The mark [E] should be at the lower side, as shown in the diagram.
8.
Connect the harness to the mechanical counter for Full Color.
9.
Attach the bracket [D] to the frame of the IOB (
10. Reassemble the machine.
11. Plug in the power cord and turn on the main power switch.
12. Enter the SP mode.
13. Set SP5987-001 to "1: ON".
14. Exit the SP mode, and then turn the machine off and on.
B230/B237/D042
x 1).