4. Replacement and Adjustment
2. If the bushings are noisy after replacement, lubricate them on both ends and the holes where the
bushings are attached with Barrierta Grease S522R.
Fusing Lamps, Hot Roller, and Pressure Roller
• If you wish to remove the pressure roller only, without removing the hot roller and fusing lamps,
please do not use this procedure. Use the procedure in the next section.
Fusing Lamps (x3) D223, D224
1. Remove the fusing unit. page 688
2. Remove harness cover [A].
3. Remove top cover [A].
710