5 Maintenance
5.4 Long-term storage cleaning
The period for performing cleaning for long-term storage, and its procedures are described below.
(1) Cleaning Period
When not using the unit for over 2 weeks, perform cleaning for long term storage.
(2) Operational procedure
Perform cleaning for long-term storage according to the following procedure.
CAUTION
• • • •
When performing cleaning for long-term storage, always wear the protective
glove supplied with the unit.
• • • •
The ink and jet wash liquid are poisonous. If skin contact occurs, wash with
soap water and rinse well.
1. Remove the screws for the valve cover (2 screws) and remove the valve cover.
No.
1
2. Turn the unit ON.
3. Follow the instructions in "4.4 Menu setup on the operation panel", and bring up the Long Save menu
on the control panel.