Error Messages and Their Causes
Error Messages with their Possible Causes and Probable Solution.
OVER CURRENT
POWER OFF THEN ON
• •
The beeper sounds
SPEED ALARM
POWER OFF THEN ON
• •
The beeper sounds
Test Modes and Troubleshooting ♦ C6 - 16
Cause
Excessive load is causing
the current to the motor to
exceed the rated value
•
Cutting conditions do
not suit the cutting
media
•
Movement of the pen
carriage is being
obstructed
•
The pen carriage was
subjected to external
pressure during cutting
•
Media scraps stuck in
moving parts and
impeding plotter
operation
•
Abnormal acceleration
rate table
Cause
•
Immediately after
turning on the plotter,
excessive force was
used to manually move
the pen carriage
•
Internal speed control is
faulty
Solution
⇒ Lower the cutting
SPEED and/or the
cutting FORCE
⇒ Turn off the plotter,
remove the obstacle,
then turn the plotter
back on.
⇒ Turn off the plotter,
remove the obstacle,
then turn the plotter
back on.
⇒ Turn off the plotter,
remove the media
scraps, then turn the
plotter back on
∗
If error occurs
frequently, contact your
sales representative or
nearest Graphtec
dealer.
Solution
⇒ Turn the plotter off then
back on again
⇒ Turn the plotter off then
back on again
∗
If error occurs
frequently, contact your
sales representative or
nearest Graphtec
dealer.