Error Messages With Their Possible Causes And Probable Solution - GRAPHTEC FC4100 series User Manual

Cutting pro fc4100 series cutting plotter
Table of Contents

Advertisement

Error Messages and Their Causes

Error Messages with their Possible Causes and Probable Solution.

OVER CURRENT
POWER OFF THEN ON
• •
The beeper sounds
SPEED ALARM
POWER OFF THEN ON
• •
The beeper sounds
Test Modes and Troubleshooting ♦ C6 - 16
Cause
Excessive load is causing
the current to the motor to
exceed the rated value
Cutting conditions do
not suit the cutting
media
Movement of the pen
carriage is being
obstructed
The pen carriage was
subjected to external
pressure during cutting
Media scraps stuck in
moving parts and
impeding plotter
operation
Abnormal acceleration
rate table
Cause
Immediately after
turning on the plotter,
excessive force was
used to manually move
the pen carriage
Internal speed control is
faulty
Solution
⇒ Lower the cutting
SPEED and/or the
cutting FORCE
⇒ Turn off the plotter,
remove the obstacle,
then turn the plotter
back on.
⇒ Turn off the plotter,
remove the obstacle,
then turn the plotter
back on.
⇒ Turn off the plotter,
remove the media
scraps, then turn the
plotter back on
If error occurs
frequently, contact your
sales representative or
nearest Graphtec
dealer.
Solution
⇒ Turn the plotter off then
back on again
⇒ Turn the plotter off then
back on again
If error occurs
frequently, contact your
sales representative or
nearest Graphtec
dealer.

Hide quick links: