Transfer elevator motor
The following steps assume that the transport unit is already removed from the
printer.
1. Detach the cable clamp, and disconnect the motor connector.
2. Remove the screws (4) which attach the transfer elevator motor to the bracket,
then remove the transfer elevator motor from the bracket.
3. Loosen the set screw (1) on the coupling using the hex wrench, then remove the
coupling from the shaft.
Mechanical System
Set screw
Coupling
Screw
Connector