Motors

Cutter motor
The cutter unit must be removed before replacing the cutter motor (see page 10–74
for cutter unit detail).
1. Disconnect the cutter motor's connector, and remove it through the hole in the
frame. Also remove the pulley drive belt.
2. Remove the set screw (1) which attaches the motor pulley to the rotating shaft,
using the hex wrench.
3. Remove the screws (3) fastening the cutter motor to the frame, then remove the
motor. A new cutter motor may now be installed.
10–46
Screw
Connector
Pulley
Set screw
Pulley drive belt