11. Adjust the distance between the belt and the conveyer base to approximately 1 cm
when the belt center is pulled up with a force of 200 grams. Firmly tighten the screws
(2 right, 2 left) to fasten the conveyer base.
Belt
Conveyer base
Vacuum fan / EPS3 / EPS4
Lift the base conveyer from the unit frame and remove the screws (3 for vacuum
fan, 2 each for EPS3 and EPS4) securing the parts to the base conveyer.
Disconnect each connector.
Connector
Screw
Vacuum fan
Conveyer base