RS–232 Serial Interface
This interface is used with bit serial devices compatible with EIA RS–232C or
CCITT V.24 standards. The interface circuit characteristics are compatible with the
Electronic Industry Association Specification.
The printer is configured as Data Terminal Equipment (DTE).
The serial data transfer baud rate is selectable from the control panel. The input
format consists of a single start bit, 7 or 8 data bits, and one or two stop bits. The
operator can set the number of data bits from the control panel. The data bits are
interpreted with the least significant bit first. The operator can also set parity
checking via the control panel. The printer interface uses a first–in/first–out buffer
with the size selectable from the control panel. The asynchronous interface accepts
data as it is provided by the host computer.
The maximum cable length from the host computer to the printer is 50 feet.
The maximum baud rate supported by the printer is 19.2 KB.
Printing at full–rated speed may require either an RS–422 or parallel connection for
wide format printing applications.
RS–232 Interface Connector Pin Assignments
The printer provides a 25–pin DB–25S connector on the right, rear side panel for
connection of a serial interface cable. This connector is also used for the RS–422
serial interface. Selection of the desired interface is determined by the position of the
RS232/422 switch located on the right, rear side panel of the printer.
Table F–3 lists the pin assignments of the RS–232 interface connector.