Feed motor (FMT) / Encoders (FME19/20)
In the feed motor block, encoders 19 and 20, along with the motor itself (with
bracket), are replacement parts, and are removed as follows:
1. Remove two (2) sensor conn ectors. Before removing, mark both connectors for
identification so that they are connected properly when installing the motors.
2. Disconnect two cable clamps, and remove the cable(s).
3. Remove the motor power connector and mark it for identification.
4. Remove the cable(s) from the two (2) harness clamps located under the motor
bracket.
10–50
Power connector
Cable clamp
Harness clamp
Sensor
Connector