Detection Errors

The errors detected by these sensors and switches are as follows:

Operator call status error

Error
Interlock action
Folding defective
Stacker full
Stacker not ready
Not auto mode
Stacker lowest position

Serviceman call status error

Error
Stacker capacity over
Motor abnormality detection 1
Motor abnormality detection 2
Motor abnormality detection 3
Motor abnormality detection 4
Optional Power Paper Stacker
Code
54
Safety sensor 1 or 2 turned off, and
interlock operated.
55
Defective folding of paper occurred (PPS
on or off time counted up).
56
The volume of folded paper has reached
capacity (SFS detected elevator table).
57
Power stacker not ready.
58
Power stacker not in auto mode.
5C
Elevator table in down position (EDS
detected elevator table).
Code
59
Elevator table is at highest or lowest
position (LIMT1 or LIMT2 detected
elevator table).
5A
Action abnormality of stacker motor has
been detected.
5A
Action abnormality of elevator motor has
been detected.
5A
Action abnormality of swinger motor has
been detected.
5A
Action abnormality of assisting arm
drive motor has been detected.