Exit; Failover - Trango Systems TrangoLINK APEX 18 User Manual

Point-to-point microwave wireless ethernet bridge high-capacity backhaul network
Table of Contents

Advertisement

exit

SYNTAX
DEFAULT VALUE
DESCRIPTION
EXAMPLE
RELATED

failover

SYNTAX
DEFAULT VALUE
DESCRIPTION
TrangoLINK Apex™ 18 User Manual Rev. 1.0
exit
N/A
Exit command is used to logout from the current node to
the lower node. Typing exit from the debug> node will
close the current session.
To Switch back to "trango-view" node from trango-config
(trango-config)# exit
(trango-view)#
To Switch to debug> node from "trango-view" node
(trango-view)# exit
debug>
To logout from the system
debug>exit
clii, config
failover <on | off>
Off
This command is to enable failover (1+1) feature and
needs to be enabled on both the units. After enabling
failover, the 2 units will participate in an election
mechanism to elect the Active unit. The other unit will
become the Standby unit. The transmitter for the Standby
unit is muted and the GigE data ports are also disabled.
However both units can receive data from the other side
of the link.
The 2 units exchange heartbeat messages between them
through the redundancy serial cable connected. The cable
needs to be connected before enabling this feature.
Section: Appendix A - Command Set Summary
Page 88