Trango Systems TrangoLINK APEX 18 User Manual page 59

Point-to-point microwave wireless ethernet bridge high-capacity backhaul network
Table of Contents

Advertisement

(trango-config)#
(trango-config)# bootimage upgrade 0
Please note the following options for the "bootimage" command:
(trango-config)# bootimage upgrade <0-5>
0 upgrades the System's FPGA
1 upgrades the System's OS
2 upgrades the System's Firmware
3 upgrades the System's PIC
4 upgrades the System's Modem
7. A reboot of the radio is required to load the new image after upgrade. If
upgrading multiple images at a time (0,1,2,3 etc) it is not required to issue reboot
after each upgrade. A single reboot can be issued after all the images have been
successfully upgraded, to reduce the downtime.
(trango-config)# reboot
The upgrade time varies depending upon the images and the size of the image.
The firmware can be verified by logging into the radio via the CLI through the "version"
command or Web browser sysinfo bottom right corner (Figure 31).
The Current images is the currently running firmware. The firmware which was replaced
will be located in the Previous images.
(trango-config)# version
Current Image Version
FPGA version:
OS version:
FW version:
PIC version:
Modem version:
RFM version:
Previous Image Version:
TrangoLINK Apex™ 18 User Manual Rev. 1.0
01270608
2p6r14b3D07230801
1p0r0D072308
215
35
1C
Section: Chapter 4 - Deployment & Installation
Page 57