1. At the login enter your username and password. The username is "admin "and
default password is "trango"
2. Enter Config mode by typing "config" and entering you write access password.
The default config mode password is "trango"
3. Enable the tftp daemon using the TFTPD command as shown below.
trango login: admin
Password:
Trango Broadband Wireless:
v1.1.0
(trango-view)# config
Password:
(trango-config)#
(trango-config)# tftpd on
tftpd:
on
SUCCESS
(trango-config)#
4. Open a MS-DOS prompt window and access the directory that you extracted the
firmware files.
C:\CD Firmware
C:\Firmware
5. Using windows TFTP command line tool, we will upload the firmware file. The tftp
syntaxs and an example are below.
TFTP [-i] host [GET | PUT] source [destination]
C:\firmware>tftp -i 192.168.100.100 put sys_fpga_v10.bin
Transfer successful: 1951744 bytes in 15 seconds, 130116 bytes/s
IF UPGRADING MULITPLE IMAGES AT A TIME. REPEAT STEP 5 WITH THE CORRECT
!
FILE NAME.
6. Once all file have been transferred successfully. Log back into the unit and apply
the updates using the "bootimage" command from the config mode. Each
firmware needs to be upgraded on the unit using the "bootimage" upgrade
command.