EXAMPLE
RELATED

rssi

SYNTAX
DEFAULT VALUE
DESCRIPTION
EXAMPLE
RELATED

rssiled

SYNTAX
DEFAULT VALUE
DESCRIPTION
EXAMPLE
TrangoLINK Apex™ 18 User Manual Rev. 1.0
To enabled rps
(trango-config)# rps_enable on
Rapid port shutdown: on
sysinfo, failover
rssi <duration>
Duration = 1-99sec
Duration = 1sec
rssi command is used to monitor the received signal level.
It is used to monitor the link, based on the specified
duration. CLI prompt will not be accessible while rssi
command is running.
RSSI value will display LO if below –90 and display HI if
above -30
To monitor the RSSI for 2sec
(trango-view)# rssi 2
1> -48.00
2> -33.86
Linktest, mse
rssiled < on | off>
On
Turn ON/OFF led for display RSSI value
To set rssi led status
(trango-config)# rssiled on
Rssiled: on
SUCCESS