Gige Port; Fiber Port (Sfp) - Trango Systems TrangoLINK APEX 18 User Manual

Point-to-point microwave wireless ethernet bridge high-capacity backhaul network
Table of Contents

Advertisement

GigE Port

No traffic is passing
• Ensure cables are connected into correct ports. Port 1 traffic passes through the
link so only Port 1 on the other side can see the traffic. Data will not pass
through the management port through the Apex system.
• Check the Ethernet cables to ensure they work properly.
• Ensure that the GigE port is enabled
Errors on GigE port
• Ensure there is no duplex mismatch.
The TrangoLINK APEX™ can be configured for Auto-negotiate, 1000 Full
duplex, 1000 Half-duplex, 100 Full duplex, 100 Half-duplex, 10 Full-duplex, and 10
Half-duplex. The setting of the TrangoLINK APEX™ should match the setting of the
connecting device.
• Verify correct Ethernet cable type is being used for GigE setting.
• The Ethernet cable connector is not properly crimped.

Fiber Port (SFP)

Not passing traffic
• Ensure the SFP module is properly installed
• Ensure the port is enabled
• Verify the correct type of fiber is being used.
• Verify the SFP module is approved by Trango