Power Connections; Input Power Connectors; Main Power - L1, L2, And L3 - Allen-Bradley Ultra1500 2092-DA1 User Manual

Digital servo amplifiers
Hide thumbs Also See for Ultra1500 2092-DA1:
Table of Contents

Advertisement

2-24
Ultra1500 Connector Data
P2
P1
L1
L2
L3
N
B1
B2
L1C
L2C
Publication 2092-UM001D-EN-P — July 2005
Figure 2.24
Simplified Ultra1500 Internal Power Circuitry
+
Diode
DC
BUS
Bridge
-
Diode
Bridge
Note: DC Bus Negative is labelled N on the drive cover, but DC- on the removable connector.

Input Power Connectors

The following power connections are made to an Ultra1500 drive through a six
position terminal connector.
Main Power – L1, L2, and L3
L1 and L2 are single-phase main AC power input connections for the
2092-DA1, 2092-DA2, and 2092 -DA3 drives. L1, L2, and L3 are three-phase
main AC power input connections for the 2092-DA4 and 2092 -DA5.
Note: The L3 terminal is not used with the 2092-DA1, 2092-DA2, and
2092-DA3 models, as they require single-phase input power.
ATTENTION
!
Dynamic Brake Diodes
Dynamic
Brake Relay
NTC
C
BUS
Soft-Start
Relay
Shunt
Circuitry
+5V
Switch
+12V
Mode
Power
-12V
Supply
IPM
The main AC power inputs should not be removed and
re-applied at a rate exceeding once every 2 minutes. Ensure
that your control timing guarantees this minimum period to
avoid damaging the drive.
U
Integrated
V
Power
Module
W
Power for
Control
Circuitry