D-2
Ultra1500 Operator Interface
Key

Mode Displays

Publication 2092-UM001D-EN-P — July 2005
The following briefly explains the MODE/SET, ENTER, and directional keys
and their use.
Name
Function
Saves the current value of the setting in
SET
memory.
Toggles the display between the four modes.
MODE
NOTE: The Status mode is the default display at
power-up.
Enter or exit a display containing the settings for
the selected mode.
ENTER
NOTE: Before exiting the display, SET must be
pressed and held until the display blinks to save
any modified value to memory.
Increments the value to a larger integer.
UP
A non-functional key in the Status mode.
Decrements the value to a smaller integer.
DOWN
A non-functional key in the Status mode.
Shifts the active digit to the left.
LEFT
An invalid key for the Status mode.
Shifts the active digit to the right.
RIGHT
An invalid key for the Status mode.

Function Mode

The Function mode displays fourteen drive functions, although four functions
have restricted access. To perform an non-reserved drive function:
1. Enter the Function mode by pressing the MODE key.
The display indicates the selected Function by displaying
(where nn is a function number from the table below).
Example
To save any change:
• Press and hold SET until the display blinks.
To advance the display through the various mode
displays:
1. Press MODE to advance from the Status
mode (default display) to Set Parameter
mode,
2. Press MODE again to advance to Monitor
mode.
3. Press MODE again to advance to the
Function mode.
4. Press MODE once more to return to the
Status mode.
To access the settings for Pr-0.00 from the
Status mode:
1. Press MODE to advance to the initial
Parameter display (PR-0.00).
2. Then press ENTER to access the parameter's
value (01 is the default setting).
In any Parameter Setting, Monitor, or Function
mode:
• Press and hold the UP key to scroll to the
maximum value.
In any Parameter Setting, Monitor, or Function
mode:
• Press and hold the DOWN key to scroll to the
minimum value.
In the Set Parameter mode:
1. Press LEFT to move from least to the most
significant digit in parameters
(PR-x.xX to PR-x.Xx.
2. Press LEFT again to move to the groups digit
(PR-X.xx).
In the Set Parameter mode:
1. Press RIGHT to move from least significant
digit in parameters to the groups digit
(PR-x.xX to PR-X.xx).
2. Press RIGHT again to move to the most
significant digit in Parameters (Pr-x.Xx).