Group 4 Parameters - Allen-Bradley Ultra1500 2092-DA1 User Manual

Digital servo amplifiers
Hide thumbs Also See for Ultra1500 2092-DA1:
Table of Contents

Advertisement

Pr-3.01 Gear Ratio Follower Lines
Range:
Default:
Units:
Applicable Operating Mode:
Ultraware Link:
Pr-3.02 Gear Ratio, Master Counts
Range:
Default:
Units:
Applicable Operating Mode:
Ultraware Link:
Pr-3.03 Encoder Output Ratio, Output Counts
Range:
Default:
Units:
Applicable Operating Mode:
Ultraware Link:
Pr-3.04 Encoder Output Ratio, Motor Counts
Range:
Default:
Units:
Applicable Operating Mode:
Ultraware Link:

Group 4 Parameters

Group 4 Parameters provide torque control settings.
Pr-4.00 Analog Current Scale
Range:
Default:
Ultra1500 Operator Interface
Gear Ratio Follower Lines
1 to 65535
1
Counts/4 = Lines
Follower
Gear Ratio Follower Lines
1 to 65535
4
Counts
Follower
Gear Ratio, Master Counts
1 to 65535
2048
Counts
All
Output Ratio, Output Counts
1 to 65535
2048
Counts
All
Output Ratio, Motor Counts
0 to 1000
333
Publication 2092-UM001D-EN-P — July 2005